Ozone Reports
Intertek, sent our product to Blue Heaven Technologies LLC, a leading Louisville, Kentucky based filter testing laboratory. They tested our electrostatic air filters for ozone levels. We are proud to report our filters passed their tests, averaging 0.0500 parts per million. As such ESC Air Filters are classified as safe for residential, Commercial, Schools and Industrial use in the United States.
OZONE REPORT
INTERTEK / BLUE HEAVEN OZONE EMISSIONS REPORT
SCOPE OF WORK In-Duct Ozone Testing of the In-duct Air Cleaner Model ECH-KJX-Z
REPORT NUMBER 104626851CRT-002
ISSUE DATE 10-MAY-2021
REVISED DATE NONE
PAGES 2
DOCUMENT CONTROL NUMBER GFT-OP-10a {21-JUNE-2019} © 2019 INTERTEK
LETTER REPORT
May 10th, 2021
Subject: In-Duct Ozone Testing of the In-duct Air Cleaner Model ECH-KJX-Z
Intertek Report No, 104626851CRT-002
Intertek Project No, G104626851
This letter report represents the results of our evaluation of the above referenced products to the requirements contained in the following standards: CSA C22.2 No 187:20, Electrostatic air cleaners, Section 7.6
Samples provided to Intertek by ESCair USA were sent to Blue Heaven Technologies LLC. Blue Heaven Technologies LLC employees conducted their protocol for testing to Section 7.6 of CSA C22.2 No. 18720, Electrostatic air cleaners. The reports from Blue Heaven Technologies LLC have been appended to this letter report.
Issuance of this letter report completes the testing covered by Intertek Project No. 6104626851. If there are any questions regarding the results contained in this report, or any of the other services offered by intertek, please do not hesitate to contact your dedicated Intertek Project Manager.